ASTM E831 PDF

Coefficient of Linear Thermal Expansion by TMA or Dilatometer ASTM E, ASTM D, ISO Scope: Linear Thermal Expansion is used to determine . This standard is issued under the fixed designation E; the 1 This test method is under the jurisdiction of ASTM Committee E37 on Thermal. ASTM E Linear Thermal Expansion of Solid Materials by Thermomechanical Analysis_机械/仪表_工程科技_专业资料。Designation: E

Author: Zulkikree Tojagal
Country: Tanzania
Language: English (Spanish)
Genre: Education
Published (Last): 19 August 2009
Pages: 407
PDF File Size: 18.79 Mb
ePub File Size: 1.77 Mb
ISBN: 534-8-31925-874-9
Downloads: 42291
Price: Free* [*Free Regsitration Required]
Uploader: Aradal

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm.

Assurance Testing Inspection Certification. Depending on the compressibility of awtm specimen and the temperature range to be investigated, a force of between 1 and mN 0. No further reproductions authorized.

Coefficient of Linear Thermal Expansion ASTM E831, ASTM D696, ISO 11359

Link to Active This link will always route e813 the current Active version of the standard. Referenced Documents purchase zstm The documents listed below are referenced within the subject standard but are not provided as part of the standard. ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

An abrupt change in slope of the expansion curve indicates a transition of the material from one state to another.

ASTM E – THERMAL EXPANSION BY TMA

Other lengths may be used, but shall be noted in the report. The furnace is raised and e31 temperature is brought to 20 degrees below the lowest temperature of interest. Unless effects of moisture are to be studied, use of dry purge gas is recommended and is essential for operation at subambient temperatures. E Terminology Relating to Thermophysical Properties. The test method may be used at lower or negative expansion levels with decreased accuracy and precision see Section The specimen is heated at a specified rate, often ten degrees a minute, over the desired temperature range.

  GACO SEALS CATALOGUE PDF

Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes. Assurance Enabling you to identify and mitigate the intrinsic risk in your operations, supply chains and business processes. The refrigerant used for cooling shall not come into direct contact with the specimen.

Global Reach Intertek is the industry leader with over 42, people in e8831, locations in over countries. NOTE 3—It d831 been found with some materials that this level of? The specimen must be flat on both ends. In a TMA, the specimen is placed in the holder at room temperature. A graph is produced. Retest of a specimen may be used only as reference and shall not be treated as an independent test of a new specimen.

Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. It is the responsibility of the user to determine the necessary equivalency prior to use. Last previous edition approved in as E — Standard Test Method f Your comments will receive careful consideration at a meeting of the responsible technical committee, asym you may attend. NOTE 4—Some materials, particularly composites, may require heat treatment to condition the specimen prior to test to relieve stresses or distortions.

  5D QSAR PDF

Coefficient of Linear Thermal Expansion ASTM E, ASTM D, ISO

Precision and Bias 6 The temperature range may be extended depending upon the instrumentation and calibration materials used. It is the responsibility of the user to determine the necessary equivalency prior to use.

Evaluating how your products and services meet and exceed quality, safety, sustainability and performance standards. Standards can be obtained from appropriate standards authorities. Active view current version of standard.

Maximum imprecision in the calculated coefficient of linear thermal expansion may be estimated from the imprecisions in the individual measurements by the following equation.

Other heating rates may be used but shall be noted in the report.

The specimen is placed in the Dilatometer at room temperature, and the height gauge is astmm and zeroed. Influence of thermal a Material Testing Coefficient of Expansion,?

Through our network of over 43, people in awtm, laboratories and offices in countries, Intertek provides quality and safety solutions to a wide range of industries around the world. Link to Active This link will always route to the current Active version of the standard. The temperature range may be extended depending upon the instrumentation and calibration materials used.